DC system ground insulation fault location detector
DC system ground insulation fault location detector
It can detect the DC system ground insulation fault location, and measure the DC system and DC feeder insulation resistance to earth





Main function and feature:

It can detect the DC system ground insulation fault location, and measure the DC bus and DC feeder insulation resistance value to earth.

It is applicable to 24/48/220/220VDC system, and 300-1000VDC system.

It can measure the DC voltage.

It can measure the AC voltage value in the DC system.

It can measure the distributed capacitance value in the DC system.

It can detect the DC bus 1 system mix connected to DC bus 2 system.

It can be used as a high precision DC current meter, the measuring precision is: 0.01mA

Main measurements parameter:

Measuring range of DC system/ DC bus resistance to earth: 0-999 K

Measuring range of DC feeder resistance to earth: 0-500 K

DC voltage measuring: 0-300VDC, 300-1000VDC

Measuring range of AC voltage in the DC system: 0-300VAC

Measuring range of distributed capacitance10uF - 200uF



Detailed Specificationsㄩ

Analyzer main specifications
Working environment

Working power:DC40V--300V

The environment temperature:  -5⊥‵+50⊥

Relative humidity: less than or equal to 90%


DC bus voltage measurement

DC voltage measurement range:0--300V, 300-1000VDC

DC voltage measurement precision:0.1V

DC voltage measurement precision:0.2%


AC voltage measurement

AC invasion voltage measurement range: 0--500V, 500-1000VAC

AC invasion voltage measurement precision: 0.1V

Distinguish-ability precision: 0.5%


DC bus insulation resistance measurement

Insulation resistance range:0--999.9K次

Insulation resistance measurement precision: 0.1K次

Insulation resistance measurement precision:≒㊣5%

Detection of ring network value: ≒200K次

System distributed capacitance measurement rangeㄩ0--999uF


Signal amplitude adjustable range

0mA, 0.25mA, 0.5mA, 1mA, 2mA
Signal amplitude frequency range
0.125Hz, 0.25Hz, 0.5Hz, 1.0Hz
Signal waveform type selection
sinusoid wave and square wave
Work mode
force signal launch and auto signal launch
Display medium and resolution
TFT, 320x240
Detector main specifications
DC feeder insulation resistance measurement

Insulation resistance range: 0--500K次

Insulation resistance measurement precision: 0.1K次

Insulation resistance measurement precision: ≒㊣10%


Spectral analysis range

Spectral analysis channel number: 1

Spectral analysis frequency range: 0.125Hz--1Hz

Frequency resolution: 0.125Hz

Voltage wave display cycle: 8s

Detects the feeder current range: 0--2A

Current measurement range: -100mA--+100mA

Display medium and resolution: TFT, 320x240


Wireless communication technology

1. Transmission rate: 2Mbps, Due to the air transmission time is short, Greatly reduce the collision phenomenon in the wireless transmission.

2. Multi-frequency point: 125, Meet the requirements of multi-point communication and frequency hopping communication.

3. Sub-miniature: built-in 2.4GHz antenna, small size, 15℅29mm

4. Low power dissipation: When work in answer mode communication, Fast air transmission and start time, Greatly reduces the current consumption.