Ture Online UPS

AC input

Phase
Three-phase three-wire
Single phase L+N
Voltage
380¡À15%VAC
220¡À15%VAC
Frequency Range
50¡À5% Hz
50¡À5% Hz
Power factor
¡Ý0.9 (linear full load)
¡Ý0.7(linear full load)
AC output


Rated Capacity
8/10/15/25/30 KVA
3/5/8/10 KVA
Rated voltage
Single phase 220VAC
Single phase 220VAC
Voltage accuracy
220¡À3%VAC
220¡À3%VAC
Output frequency
50¡À0.2Hz (battery status)
50¡À0.2Hz (battery status)
Power factor
0.8
0.8
Wave crest coefficient
3:01:00
3:01:00
Output waveform
Pure sine wave
Pure sine wave
Waveform distortion
<3% (linear full load)
<3% (linear full load)
Overload capacity

105%~125%, standby for 10 minutes and then transfer to bypass;

125%~150%, standby for 1 minute and then transfer to bypass;

150% transfer to bypass immediately. and automatically return to UPS mode after the overload is eliminated


105%~125%, standby for 10 minutes and then transfer to bypass;

125%~150%, standby for 1 minute and then transfer to bypass;

150% transfer to bypass immediately. and automatically return to UPS mode after the overload is eliminated


Current unbalance when parallel
¡Ü5%
¡Ü5%
Switching time
<4ms
<4ms
Efficiency
AC/AC>82 %; DC/AC>87%
AC/AC>82 %; DC/AC>87%

DC input



Voltage 220VDC / 110VDC 220VDC / 110VDC
Voltage range (undervoltage point can be set)
220VDC: 198VDC (default)-260VDC
110VDC: 95(default)-150VDC

220VDC: 198VDC (default)-260VDC
110VDC: 95(default)-150VDC

Over heat protection
15-30KVA: 85¡æ, 3-10KVA:75¡æ, transfer to bypass input
15-30KVA: 85¡æ, 3-10KVA:75¡æ, transfer to bypass input
Short circuit protection
Automatically current limitation, UPS shut down, the circuit breaker will trip
Automatically current limitation, UPS shut down, the circuit breaker will trip
Over voltage alarm
Over voltage alarm
Over voltage alarm
Under voltage alarm and protection
Undervoltage alarm, battery under voltage, UPS shuts down, and transfers to bypass
Undervoltage alarm, battery under voltage, UPS shuts down, and transfers to bypass
Display


LED indication
AC input light, inverter light, bypass light, battery light, overload light, fault light
AC input light, inverter light, bypass light, battery light, overload light, fault light
LCD display
Bypass, AC input, AC output, battery voltage; frequency; power factor, load percentage; UPS working status, etc.
Bypass, AC input, AC output, battery voltage; frequency; power factor, load percentage; UPS working status, etc.
Alarm


Buzzer
AC input off, battery under voltage, output overload, UPS fault, etc.
AC input off, battery under voltage, output overload, UPS fault, etc.
Communication


RS485 interface
Two RS485 channel, modbus protocol.
Two RS485 channel, modbus protocol.
Environment parameter


Operation temperature
-10~40¡æ
-10~40¡æ
Humidity
<95% (non-condensing)
<95% (non-condensing)
Noise
<65dB (one meter distance)
<65dB (one meter distance)
Size/Weight

Dimensions(mm)W¡ÁD¡ÁH


3KVA:
420x460x267£¨110VDC transformer inside£©60KGS
440x450x177£¨220VDC transformer inside£©55KGS
440x450x132£¨transformer outside£©12KGS

5KVA:
420x460x352£¨transformer inside£©85KGS

440x450x132£¨transformer outside£©12KGS


8/10/15/25/30KVA£º
440x450x132£¨transformer outside£©14-16KGS


3KVA:
420x460x267£¨110VDC transformer inside£©60KGS
440x450x177£¨220VDC transformer inside£©55KGS
440x450x132£¨transformer outside£©12KGS

5KVA:
420x460x352£¨transformer inside£©85KGS
440x450x132£¨transformer outside£©12KGS

8/10/15/25/30KVA£º
440x450x132£¨transformer outside£©14-16KGS








§¢§í§ã§ä§â§í§Ö §ã§ã§í§Ý§Ü§Ú:
§±§â§à§Õ§å§Ü§è§Ú§ñ
§° §ß§Ñ§ã
§´§Ö§ç§á§à§Õ§Õ§Ö§â§Ø§Ü§Ñ
§¯§à§Ó§à§ã§ä§Ú §Ü§à§Þ§á§Ñ§ß§Ú§Ú
Shijiazhuang Atek Electronic Technology Co., Ltd.
§´§Ö§Ý§Ö§æ§à§ß: 0086-311-88033058      §¶§Ñ§Ü§ã: 0086-311-88033026      Email: info@atekchina.cn
No.1 Building, Fangyi Industrial Park, No.365 Huaian Road, High Tech Zone, Shijiazhuang, Hebei, China